Product Overview
The MOEORW-DY5 Adjustable Low-Voltage Electroscope Starting Voltage Test Box is a specialized testing instrument designed in strict accordance with utility safety tools testing regulations (DL/T 1476-2023 Preventive Test Regulations for Electric Power Safety Tools and Equipment and DL/T 740-2014 Capacitive Voltage Detectors). It is developed for the 0.4kV low voltage electroscope verification and preventive testing of 0.4kV (400V) low-voltage electroscopes and voltage detectors, ensuring that these critical safety devices function correctly before field use.
The instrument outputs a pure sine wave voltage test source at power frequency (50Hz), accurately measuring the starting voltage of electroscopes to determine whether they remain effective and reliable. It is widely used in preventive testing programs, pre-operation on-site inspections, and acceptance testing for newly purchased or repaired electroscopes.
Application
Preventive Testing Programs: Regular (typically annual) inspection cycles for utility companies, industrial plants, and electrical contractors.
Pre-Operation Field Checks: Rapid on-site verification before crews begin work on low-voltage systems.
New Equipment Acceptance: Testing newly purchased electroscopes or units returned from repair to confirm they meet performance specifications.
Training and Demonstration: Ideal for teaching personnel proper testing techniques and electroscope functionality.
1. Full Compliance with Utility Safety Standards
Designed to meet the latest utility safety tools testing regulations (DL/T 1476-2023 and DL/T 740-2014), the MOEORW-WDY5 provides legally defensible test results that are fully traceable to national metrology standards. For 0.4kV low voltage electroscope verification, the pass/fail threshold is clearly defined: starting voltage must fall between 60V and 160V. The tester directly supports this determination, eliminating guesswork.
2. True Pure Sine Wave Output
Unlike low-cost square-wave generators, the MOEORW-WDY5 delivers a true pure sine wave voltage test source at 50Hz. This is critical because electroscope internal detection circuits are calibrated for real grid waveforms. Non-sinusoidal sources can produce false readings-our pure sine wave ensures test results match real-world grid conditions.
3. Smooth 0-220V Manual Adjustment
The manual control knob provides smooth, continuous adjustment across the full 0-220V adjustable AC voltage source range. This allows operators to slowly increase voltage as required by test procedures, precisely capturing the moment when the electroscope first emits a stable audible and visual alarm. The long-travel potentiometer design ensures repeatable and reliable readings across multiple tests.
4. Built-in Isolation Transformer for Safety
The built-in isolation transformer provides complete electrical separation between input and output circuits. This design protects operators from accidental shock and suppresses harmonics from the AC line, ensuring digital voltage readings are accurate and stable.
5. Integrated Portable Enclosure
Housed in an insulating, flame-retardant carry case, the instrument integrates all necessary components into a single portable unit. It is equally suitable for fixed laboratory use and on-site field testing, reducing setup time by over 50% compared to bulky transformer systems.
6. Mandatory Grounding Protection
A dedicated grounding terminal is provided and clearly marked. The test procedure requires a secure earth ground connection before operation, enforcing safe work practices and reducing the risk of electric shock during testing.
|
Item |
Technical Index |
|
Input Power Supply |
AC 220V±10%, 50Hz±0.1Hz |
|
Output Voltage Range |
0~220V continuously adjustable |
|
Output Waveform |
Pure sine power frequency wave |
|
Voltage Regulation Mode |
Manual stepless smooth adjustment |
|
Voltage Display |
Digital direct reading real-time display |
|
Operating Ambient Temperature |
0℃ ~ 40℃ |
|
Relative Humidity |
≤85% RH, no condensation |
|
Insulation Performance |
Input & output electrical isolation, meet safety test standards |
|
Applicable Test Object |
0.4kV (400V) low-voltage electroscopes & test pens |
|
Qualified Starting Voltage Standard |
60V ~ 160V |
|
Housing Material |
Insulated flame-retardant engineering plastic |
We provide you with free consultation services
Engineers provide guidance for installation and commissioning
Technicians can provide on-site maintenance services and receive regular training
Perfect technical consulting service system
Send your message to us: