50% of high-voltage motor stator failures stem from partial discharge (PD). Continuous insulation void discharge and slot corona cause insulation breakdown and unplanned production shutdowns.
MOEORW-5086GS is developed complying with GB/T 20833.2-2016, Q/GDW 11304.5-2015 and DL/T 2271-2021, applicable to 6kV–38kV generators, HV motors and GCB equipment for power, petrochemical, steel, mining, pharmaceutical and manufacturing industries.
This modular system consists of IPDS coupling capacitive sensors, split-core HFCT sensors, RTD temperature boards, local acquisition units and a WEB cloud platform. It conducts 24/7 synchronous collection of PD pulses and winding temperature signals, processes data via edge computing to filter interference, and outputs standardized PD graphs for early warning of insulation defects.
We support full-set bulk supply, separate sensor wholesale and OEM/ODM customization for distributors and system integrators.
1.Distributed IP Networking, Max 200 Accessible Units, Zero On-Site Configuration
Built on TCP/IP & WEB architecture; the platform auto-identifies newly added units without manual parameter setup. Suitable for phased expansion of large industrial parks, reusable tender technical materials improve bid success rate.
2.20km Fiber Long-Distance Transmission Without Repeaters
Fiber communication between acquisition units delivers lossless signal transmission. Cuts auxiliary material costs for long-span mining and chemical plants to enhance your quotation competitiveness.
3.<100ns Multi-Unit Synchronization, Accurately Separate PD & Industrial EMI
100MS/s sampling rate, 14-bit 3-channel synchronous ADC with fiber time synchronization. Maintains stable graph output in heavy-interference sites (steel mills, inverter workshops) and reduces after-sales debugging workload.
4.5PC Ultra-Low Detection Limit for Early Insulation Degradation Warning
Captures tiny internal void discharge pulses at the initial aging stage to avoid sudden motor burnout and increase end-user repurchase rate.
5.600kV Flashover Surge Resistance, Zero Hardware Damage & Data Loss
Integrated high-voltage protection circuit passes high-impulse withstand testing. Stable performance under grid lightning surges and cabinet short-circuits, lowering bulk-order after-sales costs.
6.Dual Time/Frequency-Domain Filtering, Strong Anti-Interference Performance
Onboard FPGA completes local signal denoising and feature extraction; no extra shielding accessories required for complex industrial environments.
7.Wide-Voltage Low-Power Design: AC100–240V Input, 20W Single Unit Consumption
Adapts to unstable power supply in old power rooms; low overall energy consumption for large-scale batch deployment. Operating range: -25℃~50℃, RH ≤90% non-condensing, compatible with all climate zones without differentiated stock.
8.Browser-Only WEB Platform, 10-Year Local Data Storage
No client software installation; remote cloud access supports simultaneous multi-party viewing for owners, contractors and maintenance teams. Built-in mass database meets long-term data archiving requirements for power industry acceptance.
9.Standard PD Pattern Library & Auto-Generated Inspection Reports
Supports trend curves, phase linear graphs, 2D PRPD and 3D PRPS graphs. The embedded expert library automatically distinguishes internal void discharge, slot corona and external noise, with one-click PDF report export for routine grid inspections.
10.Multi-Type Sensors for Live-Line Retrofit, One-Stop Sourcing
Split-core HFCT installs without power cut; RTD boards reuse original motor temperature wiring without altering existing temperature monitoring. Integrators can source all components from a single supplier, and separate sensor sales create extra profit channels.
Local PD Acquisition Unit
Sampling Rate: 100MS/s | ADC Resolution: 14-bit 3-channel sync | Inter-unit sync time difference: <100ns Min detectable PD: 5PC | Surge withstand: 600kV flashover | Power supply: AC100–240V | Power consumption: 20W Ambient: -25℃~50℃, RH ≤90
HFCT High-Frequency Current Sensor
Bandwidth: 0.3–30MHz | Dynamic range: 68dB | Resolution: 0.1dB | Transfer impedance ≥10mV/mA | Input impedance: 50Ω Structure: Split-core full metal shielding, live-line installatio
IPDS Coupling Capacitive Sensor
Max rated voltage: 38kV | Bandwidth: 1–20MHz | Dynamic range: 68dB, resolution 0.1dB Equipped with built-in phase reference and high-voltage protection circui
RTD Temperature Sensing Board
Bandwidth: 1–20MHz | Dynamic range: 68dB, resolution 0.1dB 6-channel RTD access, dual functions: winding temperature measurement + PD signal collection, coaxial signal outpu
Software Functions
Graph types: Trend curve, phase linear graph, PRPD, PRPS; Local storage ≥10 years; 2-level customizable alarms (Warning / Danger)
We provide you with free consultation services
Engineers provide guidance for installation and commissioning
Technicians can provide on-site maintenance services and receive regular training
Perfect technical consulting service system
Send your message to us: